Orifice plate · gas
ISO 5167-2 + AGA8
MetriSigmaBuild reproducible uncertainty budgets, linked to your instruments and traceable for audits.
Fiscal system / Measurement train 01
qb = f(d, D, Δp, ρo, ρb, Cd, ε) U · k = 2 · verified contractual case
orifice_gas_gum.json Organise each system within the real structure of the installation.
Physical equipment, certificates and effective sources linked to the system.
| Tag | Type | Symbol | Evidence | Sources |
|---|---|---|---|---|
| FE-101 | Primary element | d · D | Certificate | Dimensional |
| PDT-101 | Differential transmitter | Δp | Linked | Calibration · drift |
| PT-101 | Pressure transmitter | p | To review | Calibration |
| TT-101 | Temperature transmitter | T | Linked | Calibration · resolution |
The symbolic engine extends technologies by adding models and symbols, not parallel logic.
ISO 5167-2 + AGA8
ISO 5167-4 + AGA8
AGA9 / ISO 17089-1
API MPMS 5.3
ISO 10790
Tank and fluid properties
Prioritise systems by fiscal limit, evidence validity and calculation status.
The latest snapshot needs a metrological review before it is signed.
Technical risk · action requiredA value extracted by OCR has not yet been validated by the user.
Document · human reviewA source linked to the instrument was updated.
Traceability · change detectedDeterministic rules that explain the result without hiding the reasoning.
The recommendation is computed on the GUM and Monte Carlo result. Each signal keeps the rule that produced it and opens the data point the metrologist should review.
Equations, symbols and units managed as catalogue data.
q_b = f(d, D, Δp, ρ_o, ρ_b, C_d, ε) Reusable profiles per quantity and instrument-specific sources.
Extract certificates and apply only the fields confirmed by the user.
Upload a PDF to identify results, uncertainty and instrument data.
OCR on the original document
Value, unit, k and evidence
The user accepts or corrects
Instrument, symbol and source
Users, tenants and permissions over an isolated multi-company operation.
Access by profile, company and review scope.
Metrology · Operation · AdministrationData, catalogues and hierarchies separated by organisation.
Isolation by contextSnapshots signed with identity, date and reproducible result.
Decision traceabilityYou
Create a model or select a predefined one for your equipment or system. Upload your documentation and link input quantities, instruments, data and uncertainty sources manually or automatically.
MetriSigma
Combines Type A and B evaluations, sensitivity coefficients, correlations and degrees of freedom to obtain combined and expanded uncertainty.
JCGM 100:2008
MetriSigma
Propagates input distributions and compares the GUM result with the simulated interval at the specified coverage probability.
JCGM 101:2008
MetriSigma
Identifies the largest contributors to uncertainty. The metrology agent helps you interpret results and guide improvements to instruments and measurement conditions.
Direct contact with experts